100% Guarantee to Pass Your HP0-S17 Certification
TestInside Practice Exams for HP HP0-S17 are written to the highest standards of technical accuracy, using only certified subject matter experts and published authors for development.
1. Your customer wants to replace an existing c3000 Enclosure with a c7000 Enclosure. Which components from the c3000 Enclosure can be reused in the c7000 Enclosure? (Select three.)
A. fans
B. power supplies
C. interconnect modules
D. server and storage blades
E. Onboard Administrator module
Answer: ACD
2. A customer that usually works with a c3000 Enclosure needs to use the external DVD drive on a c7000 Enclosure and connect the drive to all servers in the c7000 Enclosure.
How can the external DVD drive on the c7000 Enclosure be accessed?
A. Use the DVD drive integrated in the c7000 Enclosure.
B. Use the DVD drive connected to the downlink port of the c7000 Enclosure.
C. Use the DVD drive connected to the USB port on an Onboard Administrator module.
D. Use the DVD drive attached through the serial/USB/video cable attached to any server blade.
Answer: C
3. Which ProLiant Essentials Value Pack is an integrated power monitoring and management application that provides centralized monitoring and control of datacenter power consumption and thermal output?
A. Insight Power Manager
B. HP Rack and Power Manager
C. Performance Management Pack
D. Vulnerability and Patch Management Pack
Answer: A
4. Which features does Virtual Connect Ethernet module (VC-Enet) provide in a network environment? (Select two.)
A. VC-Enet can stack across four enclosures in a rack.
B. VC-Enet appears as an HP ProCurve device to other network devices.
C. VC-Enet will not add any new switches for the network administrator to manage.
D. VC-Enet domains can be created directly using the Onboard Administrator console.
Answer: AC
5. You are replacing one of your redundant GbE2c interconnect switch modules in your c7000 Enclosure. What must you be aware of when you install a replacement GbE2C switch with default settings into the enclosure?
A. Crosslink ports are disabled and redundancy is lost between switches.
B. Crosslink ports are enabled and will cause a loop in your switch topology.
C. Uplink ports are disabled and must be enabled manually in the switch manager.
D. Downlink ports are disabled and must be enabled manually in the switch manager.
Answer: A
6. After replacing a failed drive in a server blade, your customer complains about long logical drive time recovery. What can you do to reduce recovery time?
A. Migrate the logical drive to RAID 6.
B. Install MPIO software on the server blade.
C. Set the rebuild priority to high on the controller.
D. Enable the Tagged Command Queuing (TCQ) feature on the hard drive.
Answer: C
7. An administrator needs to monitor performance of every drive connected to the Smart Array controller. Each drive is configured as a single logical drive.
Which tool can be used?
A. Insight Diagnostic
B. Radia Performance Manager
C. Performance Management Pack
D. Windows Server Performance Monitor
Answer: C
8. A customer has a Virtual Connect managed enclosure and needs to move one of the blades to a non-virtual connect enclosure.
What should be done so that duplicate MAC addresses and WWNs do not appear in the datacenter due to server blade deployment?
A. Enable the Reset to factory default?switch on the blade system board.
B. Run the erase utility on the blade before plugging the server to the network.
C. First delete all MAC and WWNs configurations while the server is in the VC managed enclosure and then move the server to the non-VC managed enclosure.
D. MAC addresses and WWNs are automatically returned to factory defaults when the server is moved to the non-Virtual connect enclosure so no duplicate MAC addresses or WWNs appear.
Answer: D